ROHDE & SCHWARZ ZV-Z51.70 CALIBRATION and ROHDE & SCHWARZ ZV-Z51.70 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ROHDE & SCHWARZ ZV-Z51.70 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibration / Verification Kits? Shop for Comparable Products on our   new Calibration / Verification Kits page

 
   ROHDE & SCHWARZ ZV-Z51.70 (1164.0515.70)   Description / Specification:    
ROHDE & SCHWARZ ZV-Z51.70 50 ohm 8 GHz Type-N Calibration Unit

The R&S ZV-Z51 (1164.0515.70) Type-N 8 GHz Calibration Unit features: Automatic detection of connected ports. Extremely short warm-up time. Automatic detection, installation and control via USB interface. Each calibration unit can be used with each R&S®ZVA, R&S®ZVT or R&S®ZVB model. Full multiport calibration; calibration unit has to be connected only once. Calibration of all analyzer test ports or test port subgroups. Accurate, traceable calibrations. Reliable electronic switching. Specifications. Calibration port connector type: Type N (50 ohm). Number of calibration ports: 4. Frequency range: 300 kHz to 8 GHz. Calibration time: 27s (201 points, and 1 kHz bandwidth). Damage level: 23dBm. Damage DC voltage: 12 V. Directivity: 300 kHz to 10 MHz > 40 dB, 10 MHz to 4 GHz > 46 dB, 4 GHz to 8 GHz > 40 dB. Source match: 300 kHz to 10 MHz > 23 dB, 10 MHz to 4 GHz > 40 dB, 4 GHz to 8 GHz > 36 dB. Reflection tracking: 300 kHz to 10 MHz < 0.1 dB, 10 MHz to 4 GHz < 0.04 dB, 4 GHz to 8 GHz < 0.1 dB. Load match: 300 kHz to 10 MHz > 40 dB, 10 MHz to 4 GHz > 46 dB, 4 GHz to 8 GHz > 40 dB. Transmission tracking: 300 kHz to 10 MHz < 0.2 dB, 10 MHz to 4 GHz < 0.06 dB, 4 GHz to 8 GHz < 0.1 dB.



 

Standard Calibration $730.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ROHDE & SCHWARZ ZV-Z51.70. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

White Noise
White noise is noise whose power spectral density (watts/hertz) is constant for the frequency range of interest.


Please contact us for your ROHDE & SCHWARZ ZV-Z51.70 CALIBRATION and/or ROHDE & SCHWARZ ZV-Z51.70 50 ohm 8 GHz Type-N Calibration Unit REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: